NR 439.04(5)(b) (b) Any owner or operator of a coating line or operation subject to the emission limitations of s. NR 422.085 shall collect and record the following information:
NR 439.04(5)(b)1. 1. A unique name or identification number for each coating, as applied.
NR 439.04(5)(b)2. 2. The daily average VOC emission rate as calculated using the equation in s. NR 422.085 (4) (b), and all information identified in s. NR 422.085 (4) (b) and (c) necessary to calculate the daily average VOC emission rate.
NR 439.04(5)(c) (c) Any owner or operator of a coating line or operation subject to the emission limitations of s. NR 422.13 shall collect and record the following information:
NR 439.04(5)(c)1. 1. A unique name or identification number for each coating, as applied.
NR 439.04(5)(c)2. 2. The surface area in units of feet squared of coated finished product.
NR 439.04(5)(c)3. 3. The amount of VOC per area of surface to which coatings are applied in units of pounds of VOC per 1000 ft2, regardless of the number of coats applied.
NR 439.04(5)(d)1.1. Any owner or operator of a printing line or operation subject to the emission limitations of s. NR 422.14 (2) (a) or (b) shall collect and record the following information:
NR 439.04(5)(d)1.a. a. A unique name or identification number for each ink, as applied.
NR 439.04(5)(d)1.b. b. The VOC content of each ink, as applied, expressed in units necessary to determine compliance.
NR 439.04(5)(d)2. 2. Any owner or operator of a printing line or operation subject to the emission limitation in s. NR 422.14 (2) (c) shall collect and record the following information for each day of operation:
NR 439.04(5)(d)2.a. a. Monitoring data for the control device.
NR 439.04(5)(d)2.b. b. A log of operating time for the capture system, control device, monitoring equipment and the associated coating or printing line or operation.
NR 439.04(5)(d)2.c. c. A maintenance log for the capture system, control device and monitoring equipment detailing all routine and non-routine maintenance performed and including dates and duration of any outages.
NR 439.04(5)(e) (e) Any owner or operator of a coating or printing line or operation that is subject to an emission limitation in ss. NR 422.05 to 422.135 or 422.145 to 422.155, and that is achieving compliance with the applicable emission limitation by a method allowed under s. NR 422.04 (2) (b), (c), or (d) shall, in addition to the applicable information required under pars. (a) to (d), collect and record the following information for each day of operation:
NR 439.04(5)(e)1. 1. The allowable emission rate pursuant to ss. NR 422.05 to 422.155 in pounds per gallon of coating, excluding water.
NR 439.04(5)(e)2. 2. The amount of each coating or ink in gallons, delivered to the applicator.
NR 439.04(5)(e)3. 3. The volume fraction of solids in each coating or ink, delivered to the applicator.
NR 439.04(5)(e)4. 4. The density of the VOC used in each coating or ink in pounds per gallon, delivered to the applicator.
NR 439.04(5)(e)5. 5. The total allowable emissions as calculated under s. NR 422.04 (4).
NR 439.04(5)(e)6. 6. The actual emissions for those coatings or inks for which allowable emissions were calculated under s. NR 422.04 (4), when considering the control device.
NR 439.04(5)(e)7. 7. Control device monitoring data.
NR 439.04(5)(e)8. 8. A log of operating time for the capture system, control device, monitoring equipment and the associated coating or printing line or operation.
NR 439.04(5)(e)9. 9. A maintenance log for the capture system, control device and monitoring equipment detailing all routine and non-routine maintenance performed including dates and duration of any outages.
NR 439.04(5)(f) (f) Any owner or operator of a surface coating or printing facility that is subject to one or more emission limitations under ss. NR 422.05 to 422.151, and that is achieving compliance with the applicable emission limitation or limitations by internal offsets as allowed under s. NR 425.05 shall, in addition to the applicable information required under pars. (a) to (d), collect and record the following information for each day of operation for each coating or ink involved in the internal offset:
NR 439.04(5)(f)1. 1. The amount of coating material or ink in gallons, delivered to the applicator.
NR 439.04(5)(f)2. 2. The volume fraction of solids in the coating or ink, delivered to the applicator.
NR 439.04(5)(f)3. 3. The density of the VOC used in the coating or ink in pounds per gallon, delivered to the applicator.
NR 439.04(5)(g) (g) Any owner or operator of a surface coating or printing line that is subject to an emission limitation in ss. NR 422.05 to 422.155, and that is achieving compliance with the applicable emission limitation by in-line averaging as allowed under s. NR 422.04 (1) shall, in addition to the information required under pars. (a) and (d), collect and record the following information for each day of operation for each coating or printing line:
NR 439.04(5)(g)1. 1. When achieving compliance under s. NR 422.04 (1) (a):
NR 439.04(5)(g)1.a. a. The name or identification number of each coating applied on each coating line.
NR 439.04(5)(g)1.b. b. The volume of each coating applied in gallons, excluding water.
NR 439.04(5)(g)1.c. c. The daily volume-weighted average VOC content of all coatings applied on each coating line as defined in s. NR 422.04 (1) (a).
NR 439.04(5)(g)2. 2. When achieving compliance under s. NR 422.04 (1) (b) 1.:
NR 439.04(5)(g)2.a. a. The name or identification number of each ink applied on each printing line.
NR 439.04(5)(g)2.b. b. The volume of each ink applied in gallons.
NR 439.04(5)(g)2.c. c. The daily volume-weighted average VOC content of all inks applied on each printing line as defined in s. NR 422.04 (1) (b) 1.
NR 439.04(5)(g)3. 3. When achieving compliance under s. NR 422.04 (1) (b) 2.:
NR 439.04(5)(g)3.a. a. The name or identification number of each ink applied on each printing line.
NR 439.04(5)(g)3.b. b. The volume of each ink applied in gallons, excluding water.
NR 439.04(5)(g)3.c. c. The daily volume-weighted average VOC content of all inks applied on each printing line as defined in s. NR 422.04 (1) (b) 2.
NR 439.04(6)(a)(a) If an owner or operator of a solvent cleaning operation employs a thermal incinerator or catalytic incinerator to achieve and maintain compliance as allowed in any section in ch. NR 422 or in s. NR 423.037, the owner or operator shall comply with the following requirements:
NR 439.04(6)(a)1. 1. Continuous temperature monitoring and continuous temperature recording equipment shall be installed and operated to accurately measure the operating temperature for the control device.
NR 439.04(6)(a)2. 2. The following information shall be collected and recorded each day of operation of the solvent cleaning operation and the control device, and the information shall be maintained at the facility for a period of 5 years:
NR 439.04(6)(a)2.a. a. A log or record of the operating time for the control device, monitoring equipment, and the associated solvent cleaning operation.
NR 439.04(6)(a)2.b. b. For thermal incinerators, all 3-hour periods of operation during which the average combustion temperature was more than 50 degrees Fahrenheit below the average combustion temperature during the most recent emission test that demonstrated that the solvent cleaning operation was in compliance.
NR 439.04(6)(a)2.c. c. For catalytic incinerators, all 3-hour periods of operation during which the average temperature of the dryer exhaust gases immediately before the catalyst bed was more than 50 degrees Fahrenheit below the average temperature of the dryer exhaust gases during the most recent emission test that demonstrated that the solvent cleaning operation was in compliance, and all 3-hour periods during which the average temperature difference across the catalyst bed was less than 80% of the average temperature difference during the most recent emission test that demonstrated that the solvent cleaning operation was in compliance.
NR 439.04(6)(b) (b) If an owner or operator of a solvent cleaning operation employs a carbon adsorption system to achieve and maintain compliance as allowed in any section in ch. NR 422 or in s. NR 423.037, the owner or operator shall comply with the following requirements:
NR 439.04(6)(b)1. 1. One of the following types of monitoring and recording equipment shall be installed and operated for the carbon adsorption system:
NR 439.04(6)(b)1.a. a. A continuous emission monitoring and recording system that is capable of accurately measuring and recording the concentration of organic compounds in the exhaust gases from the carbon adsorption system.
NR 439.04(6)(b)1.b. b. Monitoring and recording equipment that are capable of accurately measuring and recording the total mass steam flow rate for each regeneration cycle of each carbon bed.
NR 439.04(6)(b)1.c. c. Monitoring and recording equipment that are capable of accurately measuring and recording the temperature of each carbon bed after each regeneration and cooling cycle.
NR 439.04(6)(b)2. 2. The following information shall be collected and recorded each day of operation of the solvent cleaning operation and the carbon adsorption system, and the information shall be maintained at the facility for a period of 5 years:
NR 439.04(6)(b)2.a. a. A log or record of the operating time for the carbon adsorption system, monitoring equipment, and the associated solvent cleaning operation.
NR 439.04(6)(b)2.b. b. For a carbon adsorption system that employs a continuous emission monitoring and recording system to measure and record the concentration of organic compounds in the exhaust gases, all 3-hour periods of operation during which the average concentration level or reading in the exhaust gases is more than 20% greater than the exhaust gas organic compound concentration level or reading measured by the most recent performance test that demonstrated that the solvent cleaning operation was in compliance.
NR 439.04(6)(b)2.c. c. For a carbon adsorption system that employs monitoring and recording equipment to measure and record the total mass steam flow rate for each regeneration cycle of each carbon bed, all carbon bed regeneration cycles during which the total mass steam flow rate was more than 10% below the total mass steam flow rate during the most recent performance test that demonstrated that the solvent cleaning operation was in compliance.
NR 439.04(6)(b)2.d. d. For a carbon adsorption system that employs monitoring and recording equipment to measure and record the temperature of each carbon bed after each regeneration and cooling cycle, all carbon bed regeneration cycles during which the temperature of the carbon bed after the regeneration and cooling cycle was more than 10% greater than the carbon bed temperature during the most recent performance test that demonstrated that the solvent cleaning operation was in compliance.
NR 439.04 History History: Renum. from NR 154.06 (3), and am. Register, September, 1986, No. 369, eff. 10-1-86; renum. from NR 439.03 and am. Register, September, 1987, No. 381, eff. 10-1-87; am. (2), cr. (3), Register, February, 1990, No. 410, eff. 3-1-90; am. (1) (a), Register, May, 1992, No. 437, eff. 6-1-92; am. (1) (a) and (2), r. and recr. (3), cr. (4) and (5), Register, December, 1993, No. 456, eff. 1-1-94; am. (4) (intro.) and (5) (a), Register, June, 1994, No. 462, eff. 7-1-94; am. (5) (a) (intro.), Register, August, 1994, No. 464, eff. 9-1-94; renum. (5) (d) (intro.) to be (5) (d) 1. intro. and am., renum. (5) (d) 1. and 2. to be (5) (d) 1. a. and b., cr. (5) (d) 2., am. (5) (e) (intro.), Register, June, 1995, No. 474, eff. 7-1-95; CR 00-174: am. (5) (a) (intro.), Register August 2001 No. 548, eff. 9-1-01; CR 11-005: am. (4) (intro.), (d), cr. (4) (f), (g), (h), (6) Register January 2012 No. 673, eff. 2-1-12; CR 20-088: am. (4) (intro.), (a) to (d), r. (4) (e) to (g), am. (5) (a) (intro.), renum. (5) (a) 2. to (5) (a) 2. (intro.) and a. and am., cr. (5) (a) 2. b., am. (5) (f) (intro.) Register May 2022 No. 797, eff. 6-1-22.
NR 439.05 NR 439.05Access to records; inspections.
NR 439.05(1)(1)No person may deny information or access to records relating to emissions or any other records required to be kept to an authorized representative of the department.
NR 439.05(2) (2)No person may deny entry or access at any reasonable time to an authorized representative of the department for the purposes of inspection of facilities, equipment, including monitoring and air pollution control equipment, practices or operations regulated or required by the department, or at any time when an air pollution episode condition exists or is believed imminent. No person may obstruct, hamper or interfere with any inspection. The department, if requested, shall furnish to the owner or operator of the premises a report setting forth all facts found which relate to compliance status.
NR 439.05(3) (3)The department may, for the purpose of determining a source's compliance with applicable requirements, sample or monitor at reasonable times production materials or other substances or operational parameters.
NR 439.05 History History: Renum. from NR 154.06 (4) and am. Register, September, 1986, No. 369, eff. 10-1-86; renum. from NR 439.04 and am. Register, September, 1987, No. 381, eff. 10-1-87; renum. to be (1), (2) renum. from NR 439.09 and am., Register, May, 1992, No. 437, eff. 6-1-92; am. (1) and (2), cr. (3), Register, December, 1993, No. 456, eff. 1-1-94.
NR 439.055 NR 439.055Methods and procedures for determining compliance using instrumentation of air pollution control equipment and source processes.
NR 439.055(1)(1)The department may require the owner or operator of a source to install and operate instrumentation to monitor the operation of the source or of air pollution control equipment. Unless otherwise specified by the department, for the following types of air pollution control equipment, the indicated operational variables shall, at a minimum, be monitored:
NR 439.055(1)(a) (a) Baghouses — pressure drop across the baghouse in inches of water.
NR 439.055(1)(b) (b) Mechanical collectors — pressure drop across the collector in inches of water.
NR 439.055(1)(c) (c) Electrostatic precipitators — primary and secondary voltage in volts, primary and secondary current in amps, and sparking rate in sparks per minute.
NR 439.055(1)(d) (d) Incinerators — temperature in the primary chamber and the afterburner in degrees Fahrenheit or Celsius (centigrade).
NR 439.055(1)(e) (e) Wet scrubbers for control of particulates — pressure drop across the scrubber and demister in inches of water and scrubber liquor flow in gallons per minute.
NR 439.055(1)(f) (f) Absorption equipment for control of gases — pressure drop across the absorber and demister in inches of water, and pH of the absorbing fluid, if appropriate.
NR 439.055(1)(g) (g) Adsorption equipment — pressure drop across the adsorber and prefilter in inches of water, and temperature within the adsorber in degrees Fahrenheit or Celsius (centigrade).
NR 439.055(2) (2)When the department requires instrumentation to monitor the operation of a source or of air pollution control equipment, the following monitoring and recording frequencies shall, at minimum, be used:
NR 439.055(2)(a) (a) Temperature in the primary chamber and afterburner of an incinerator shall be monitored and recorded every 15 minutes.
NR 439.055(2)(b) (b) The following operational variables shall be measured and recorded once for every 8 hours of source operation or once per day, whichever yields the greater number of measurements:
NR 439.055(2)(b)1. 1. Pressure drop across baghouses, mechanical collectors, wet scrubbers, absorption equipment or adsorption equipment.
NR 439.055(2)(b)2. 2. Current and secondary current in electrostatic precipitators.
NR 439.055(2)(b)3. 3. Voltage in electrostatic precipitators.
NR 439.055(2)(b)4. 4. The sparking rate from electrostatic precipitators.
NR 439.055(2)(b)5. 5. Flow of liquor in wet scrubbers used for particulate control.
NR 439.055(2)(b)6. 6. pH of absorption scrubbing fluid.
NR 439.055(3) (3)When the department requires instrumentation to monitor the operation of air pollution control equipment, or to monitor source performance, the instrument shall measure operational variables with the following accuracy:
NR 439.055(3)(a) (a) The temperature monitoring device shall have an accuracy of 0.5% of the temperature being measured in degrees Fahrenheit or $ 5°F of the temperature being measured, or the equivalent in degrees Celsius (centigrade), whichever is greater.
NR 439.055(3)(b) (b) The pressure drop monitoring device shall be accurate to within 5% of the pressure drop being measured or within $1 inch of water column, whichever is greater.
NR 439.055(3)(c) (c) The current, voltage, flow or pH monitoring device shall be accurate to within 5% of the specific variable being measured.
NR 439.055(4) (4)All instruments used for measuring source or air pollution control equipment operational variables shall be calibrated yearly or at a frequency based on good engineering practice as established by operational history, whichever is more frequent.
NR 439.055(5) (5)The department may require, in an operation permit or order, the measurement of a greater number of source or air pollution control operational variables, more frequent monitoring of operational variables, more accurate measurement of operational variables or more frequent calibration of monitoring equipment than those required under subs. (1) to (4) if the department determines that these requirements are necessary to ensure that the source does not exceed an applicable emission limit, or to ensure that the requirements of chs. NR 400 to 499 are met.